Skip to content

MdiForward ​

Ma and Razavi's MDI-BB84 observables at the limits that pin them

6/6 passed in 0ms

TestWhat it doesResult
test_bell_ceilingWithout dark counts Y11 is eta_a*eta_b/2, two of the four Bell states identified.✅ pass
test_diag_interferesThe diagonal gain over the rectilinear one is 2.000001, 2.000050 and 2.010069 at mu = 1e-5, 0.001 and 0.2.✅ pass
test_diag_quarterThe diagonal-basis QBER of two independent coherent sources tends to 1/4 + e_d/2 as the signal weakens, not to the misalignment.✅ pass
test_gain_scalingHalving one arm efficiency halves the single-photon-pair yield, halving both quarters it.✅ pass
test_pair_errorWithout dark counts the single-photon-pair error rate is the misalignment itself, in both bases and at every arm efficiency.✅ pass
test_rect_errorWithout dark counts the rectilinear error rate is the misalignment at any intensity.✅ pass